Radiation Oncology/Treatment planning/Motion



Tumor and Organ At Risk Motion


Abdominal Tumors

edit
  • PMID 15817361, 2005 — "The correlation between internal and external markers for abdominal tumors: implications for respiratory gating." Gierga BP et al. Int J Radiat Oncol Biol Phys. 2005 Apr 1;61(5):1551-8.
    • 4 pts. liver tumors.
  • PMID 15050340, 2004 — "Quantification of respiration-induced abdominal tumor motion and its impact on IMRT dose distributions." Gierga BP et al. Int J Radiat Oncol Biol Phys. 2004 Apr 1;58(5):1584-95.
    • Used surgical clips and fluroscopy. 7 pts (6 pancreas, 1 liver).
    • Average peak-to-peak motion (i.e., twice the amplitude): LR < 2mm, CC 7.4mm, AP 3.8mm
    • IMRT plan using PTV margin of 8 mm (accounting for tumor motion only, not setup inaccuracy)


Abdominal Organs

edit
  • Pittsburgh; 2006 PMID 16690437 -- "Abdominal organ motion measured using 4D CT." (Brandner ED, Int J Radiat Oncol Biol Phys. 2006 Jun 1;65(2):554-60.)
    • 4D CT scanning, 13 patients
    • sup-inf organ motion: liver 1.3 cm, spleen 1.3 cm, left kidney 1.1 cm, right kidney 1.3 cm
    • Conclusion: 4D CT can accurately measure abdominal organ motion throughout respiration