HydroGeoSphere/Free Drainage
Assigns a free drainage boundary condition, as described in Section 3.7.1 to nodes on all faces in the specified set. These faces should be on the surface of the domain.
The following instruction can be used as input to the Type instruction inside the Boundary condition...End instruction group to assign free drainage boundary conditions:
Free drainage
editSets the input type to be a free drainage boundary condition.
- • • •
- • • •
For example:
boundary condition
type
free drainage
face set
outflow
end
This example shows that a time-value table is not mandatory. However, if you wish to turn the free drainage boundary condition on or off, then this can be accomplished by including a time value table instruction:
boundary condition
type
free drainage
face set
outflow
time value table
0.0 1.0
10.0 -99999.
end
end