This page was imported and needs to be de-wikified. Books should use wikilinks rather sparsely, and only to reference technical or esoteric terms that are critical to understanding the content. Most if not all wikilinks should simply be removed. Please remove {{dewikify}} after the page is dewikified. |
Affinity chromatography is a method of separating biochemical mixtures and based on a highly specific biological interaction such as that between antigen and antibody, enzyme and substrate, or receptor and ligand. Affinity chromatography combines the size fractionation capability of gel permeation chromatography with the ability to design a chromatography that reversibly binds to a known subset of molecules. The method was by Cuatrecasas P, Wilchek M,and Meir Wilchek for which the Wolf Prize in Medicine was awarded in 1987. Due to its interdisciplinary nature, affinity chromatography has been the means by which many scientists from different disciplines have been introduced in to the fields of modern biology.
Uses
editAffinity chromatography can be used to:
- Purify and concentrate a substance from a mixture into a buffering solution
- Reduce the amount of a substance in a mixture
- Discern what biological compounds bind to a particular substance, such as drugs
- Purify and concentrate an enzyme solution.
Principle
editThe immobile phase is typically a gel matrix, often of agarose; a linear sugar molecule derived from algae. Usually the starting point is an undefined heterogeneous group of molecules in solution, such as a cell lysate, growth medium or blood serum. The molecule of interest will have a well known and defined property which can be exploited during the affinity purification process. The process itself can be thought of as an entrapment, with the target molecule becoming trapped on a solid or stationary phase or medium. The other molecules in solution will not become trapped as they do not possess this property. The solid medium can then be removed from the mixture, washed and the target molecule released from the entrapment in a process known as elution. Possibly the most common use of affinity chromatography is for the purification of recombinant proteins.
Batch and column setup
editBinding to the solid phase may be achieved by column chromatography whereby the solid medium is packed onto a column, the initial mixture run through the column to allow setting, a wash buffer run through the column and the elution buffer subsequently applied to the column and collected. These steps are usually done at ambient pressure. Alternatively binding may be achieved using a batch treatment, by adding the initial mixture to the solid phase in a vessel, mixing, separating the solid phase (for example), removing the liquid phase, washing, re-centrifuging, adding the elution buffer, re-centrifuging and removing the eluate.
Sometimes a hybrid method is employed, the binding is done by the batch method, then the solid phase with the target molecule bound is packed onto a column and washing and elution are done on the column.
A third method,expanded bed adsorption, which combines the advantages of the two methods mentioned above, has also been developed. The solid phase particles are placed in a column where liquid phase is pumped in from the bottom and exits at the top. The gravity of the particles ensure that the solid phase does not exit the column with the liquid phase.
Specific uses
editAffinity chromatography can be used in a number of applications, including nucleic acid purification, protein purification from cell free extracts, and purification from blood.
Immunoaffinity
editAnother use for the procedure is the affinity purification of antibodies from blood serum. If serum is known to contain antibodies against a specific antigen (for example if the serum comes from an organism against the antigen concerned) then it can be used for the affinity purification of that antigen. This is also known as Immunoaffinity Chromatography. For example if an organism is immunised against a GST-fusion protein it will produce antibodies against the fusion-protein, and possibly antibodies against the GST tag as well. The protein can then be covalently coupled to a solid support such as agarose
For thoroughness the GST protein and the GST-fusion protein can each be coupled separately. The serum is initially allowed to bind to the GST affinity matrix. This will remove antibodies against the GST part of the fusion protein. The serum is then separated from the solid support and allowed to bind to the GST-fusion protein matrix. This allows any antibodies that recognize the antigen to be captured on the solid support. Elution of the antibodies of interest is most often achieved using a low pH buffer such as glycine pH 2.8. The eluate is collected into a neutral tris or phosphate buffer, to neutralize the low pH elution buffer and halt any degradation of the antibody's activity. This is a nice example as affinity purification is used to purify the initial GST-fusion protein, to remove the undesirable anti-GST antibodies from the serum and to purify the target antibody.
A simplified strategy is often employed to purify antibodies generated against peptide antigens. When the peptide antigens are produced synthetically, a terminal cysteine residue is added at either the N- or C-terminus of the peptide. This cysteine residue contains a sulfhydryl functional group which allows the peptide to be easily conjugated to a carrier protein (e.g.Keyhole limpet hemocyaninKLH). The same cysteine-containing peptide is also immobilized onto an agarose resin through the cysteine residue and is then used to purify the antibody.
Immobilized metal ion affinity chromatography
editImmobilized metal ion affinity chromatography (IMAC) is based on the specific coordinate covalent bond of amino acids, particularly histidine, to metals. This technique works by allowing proteins with an affinity for metal ions to be retained in a column containing immobilized metal ions, such as cobalt, nickel, copper for the purification of histidine containing proteins or peptides, iron, zinc or gallium for the purification of phosphorylated proteins or peptides. Many naturally occurring proteins do not have an affinity for metal ions, therefore recombinant DNA technology can be used to introduce such a protein tag into the relevant gene. Methods used to elute the protein of interest include changing the pH, or adding a competitive molecule, such as imidazole.
Recombinant proteins
editPossibly the most common use of affinity chromatography is for the purification of recombinant proteins. Proteins with a known affinity are protein tagged in order to aid their purification. The protein may have been genetically modified so as to allow it to be selected for affinity binding, this is known as a fusion protein. Tags include glutathione-S-transferase tags. have an affinity for nickel or cobalt ions which are Coordinate covalent bond|coordinated] with a chelator for the purposes of solid medium entrapment. For elution, an excess amount of a compound able to act as a metal ion ligand, such as imidazole, is used. GST has an affinity for glutathione -commercially available immobilized as glutathione agarose. For elution, excess glutathione is used to displace the tagged protein.
Lectins
editLectin affinity chromatography is a form of affinity chromatography where lectins are used to separate components within the sample. Lectins, such as Concanavalin A are proteins which can bind specific carbohydrate (sugar) molecules. The most common application is to separate proteins based on their Glycosylation groups.